Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure

Andrea Cioncolini*, Lorenzo Santini, Marco E. Ricotti

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

Experimental pressure drop results on boiling water flow through three helical coils of tube inner diameter of 4.03 mm and 4.98 mm and coil diameter to tube diameter ratio of 26.1, 64.1 and 93.3 are presented. Both subcooled and saturated flow boiling are investigated, covering operating pressures from 120 to 660 kPa, mass fluxes from 290 to 690 kg m-2 s-1 and heat fluxes from 50 to 440 kW m-2. Existing correlations for subcooled flow pressure drop are found not capable to fit the present subcooled database, while the measurements in saturated flow conditions are successfully reproduced by existing correlations for both straight and coiled pipe two-phase flow. The experimental database is included in tabular form.

Original languageEnglish
Pages (from-to)1301-1312
Number of pages12
JournalExperimental Thermal and Fluid Science
Volume32
Issue number6
DOIs
StatePublished - May 2008
Externally publishedYes

Keywords

  • Coiled tubes
  • Curved channels
  • Flow boiling
  • Helical coils
  • Pressure drop
  • Two-phase flow

Fingerprint

Dive into the research topics of 'Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure'. Together they form a unique fingerprint.

Cite this