Performance improvement of horizontal evaporator-condenser desalination units

S. Sideman*, D. Moalem, R. Semiat

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

17 Scopus citations

Abstract

An experimental work, aimed at appraising the authors' theoretical analysis of the simultaneous film evaporation outside and condensation inside horizontal tubes, is presented. The data indicate that for ReN > 150, the laminar flow model must be modified to account for ripples and waves caused by the drops falling down on the tubes. The effects of ReNand ΔT on the overall transfer coefficient are very small. The effect of Tυ is small, particularly in the presence of air. The predicted effects of utilizing non-circular conduits is validated, and a 20% increase in the overall transfer coefficient was measured for elongated elliptical conduits.

Original languageEnglish
Pages (from-to)221-233
Number of pages13
JournalDesalination
Volume21
Issue number2
DOIs
StatePublished - Jul 1977
Externally publishedYes

Fingerprint Dive into the research topics of 'Performance improvement of horizontal evaporator-condenser desalination units'. Together they form a unique fingerprint.