Detection of fouling on RO modules by residence time distribution analyses

David Hasson*, Alexander Drak, Chagai Komlos, Qingfeng Yang, Raphael Semiat

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

A simple and reliable technique for on line detection and diagnosis of scaling and fouling deposits could improve significantly operational control of RO plants. This paper presents results of an ongoing research project aiming to develop a novel method for online detection of membrane fouling by a residence time distribution (RTD) technique. The method is based on determination of flow dispersion intensities from online RTD signals that can be simply measured. The systems investigated in this paper are spiral wound membranes fouled with either Mg(OH)2 or CaCO3. Analyses of RTD data of fouled membranes show that an increasing membrane permeability loss is accompanied by a systematic increase in the dispersion coefficient, thus providing an indicator for detecting a fouling event. It is also found that the magnitude of the dispersion coefficient is affected by deposit morphology, thus indicating the possibility for diagnosing the nature of the fouling deposit. Another fouling indicator may be derived from the observation that the extent of the dead volume monitored by the RTD signal increases with the fouling level while dead volumes are absent in clean modules.

Original languageEnglish
Pages (from-to)132-144
Number of pages13
JournalDesalination
Volume204
Issue number1-3 SPEC. ISS.
DOIs
StatePublished - 5 Feb 2007
Externally publishedYes

Keywords

  • Dispersion coefficient
  • Fouling
  • Residence time distribution
  • Scaling
  • Spiral wound module

Fingerprint Dive into the research topics of 'Detection of fouling on RO modules by residence time distribution analyses'. Together they form a unique fingerprint.

Cite this